Recovery System
156
Service Manual – Advance 7765 / Nilfisk CR1500
Problem
Cause
Correction
Squeegee vacuum
fan motor not
running.
Circuit breaker CB8 is
tripped.
Reset the circuit breaker.
Squeegee fan motor
solenoid valve not operating
correctly.
•
Check the wiring from the Squeegee Blade Switch
to the fan motor solenoid valve. There should be 0
volts to the solenoid when the fan motor is on and
12 VDC to the solenoid when the fan motor is off.
•
Check the solenoid coil resistance. If not 6.6
ohms ±10% , replace the solenoid. Also see the
Recovery System Wiring Diagram
.
Vacuum Test
1. Remove the rear squeegee assembly from the
Squeegee Support Weldment
.
2.
Block the
Squeegee Support Weldment
.
3. Install the
Vacuum Test Gauge
into the
Hose
.
4. Start the engine and switch the squeegee blade switch to the “lower” position. The
Vacuum Test Gauge
should read 30 inches of water or higher.
Squeegee
Support
Weldment
Vacuum
Test
Gauge