8/00 Form No. 56040723
© 2000 Printed in USA, Nilfisk-Advance, Inc.
1
FRONT
2
3
4
A
B
56410174 BACK-UP ALARM KIT
For Advance Hydro-Retriever™ 3800 (model 56410000) / Nilfisk BR 1100
CONTENTS OF KIT
ITEM
REF. NO.
QTY
DESCRIPTION
56040723
1
Instruction Sheet
1
56009033
2
Scr, Hex Thd Form 1/4-20 x .50
2
56409232
1
Back-Up Alarm
3
56409538
2
Insulator, Terminal
4
56410171
1
Wire Assembly, Pigtail
INSTALLATION INSTRUCTIONS
WARNING!
DISCONNECT BATTERIES BEFORE SERVICING.
1
If Items
(2, 3 & 4)
are not already assembled together, do so before proceeding.
2
Slip one Terminal Insulator
(3)
over each wire of the Wire assembly
(4)
as shown.
3
Attach the RED wire from Wire Assembly
(4)
to the (+) terminal and the BLACK wire
from Wire Assembly
(4)
to the (-) termi-
nal of the Back-Up Alarm
(2)
, then slide
the Terminal Insulators
(3)
over each ter-
minal.
4
Under the left rear corner of the machine,
there are (2) pre-drilled holes
(A)
. Mount
the Back-Up Alarm
(2)
with the (2) Screws
(1)
from the kit as shown.
5
Route the Wire Assembly
(4)
up through
hole
(B)
.
6
Drain and tip the recovery tank back.
7
Next to the squeegee lift actuator at the
rear of the machine there is a bundle of
wire connectors. Find the wire connec-
tor which has (1) BLK wire and (1) WHT
wire connected to it and remove the pro-
tective plug. Plug Wire Assembly
(4)
into
this connector.
8
Reconnect the batteries and test the
Back-Up Alarm by driving the machine in
reverse.