![Nilfisk-Advance BR 1100 Service Manual Download Page 69](http://html.mh-extra.com/html/nilfisk-advance/br-1100/br-1100_service-manual_1693238069.webp)
FORM NO. 56043058 Hydro-Retriever™ 3800 / 2042 / BR 1100 -
67
ELECTRICAL SYSTEM
Error Code
Fault Description
Troubleshooting Action
Err07
Scrub motor overload
Check for binding in rotation of brushes or improper brush lift actuator
operation. 2. Check the negative supply cable at the brush motor for
a wiring problem or improper modifications (this is a special cable and
must be replaced with the original OEM PN 56410113). 3. Check to
see that the proper brush type is selected
***
(disc or cyl).
Err08
Scrub motor severe overload
1. Same as Err07. 2. Check for short circuit in brush motor or wiring.
3. Inspect gearbox for failure. Repair or replace.
Err09
Scrub motor circuit open (**)
1. Check for open in brush motor wiring or defective motor. 2. Check
the negative supply cable at the brush motor for a wiring problem or
improper modifications (this is a special cable and must be replaced
with the original OEM PN 56410113). 3. Replace defective brush
motor contactor. 4. Check if brushes are installed.
Err10
Scrub motor contactor
Check solenoid for welded contacts (continuity test). If
contacts shorted
welded replace solenoid.
Err12
Scrub motor contactor coil overload
1. Check for wiring problems. 2. Check coil resistance if below 102
ohms replace solenoid.
Err13
Scrub motor contactor coil
1. Same as error code 12. 2. Shorted coil. Replace.
severe overload
Err14
Scrub motor contactor coil
1. Check for an open in the coil wiring 2. Check solenoid coil for high
circuit open (**)
resistance (infinity). Repair or replace. 3. Controller failure (replace).
Err17
Scrub motor cable thermistor fault
Machine exposed to a very cold or hot operating temperature. Allow
machine to be warmed or cooled to room temperature. Temp range
32
º
F to 185
º
F (0 to 85
º
C) 2. Cable failure, replace the brush motor
negative cable assemble (this is a special cable and must be replaced
with an original OEM PN 56410113). Note: Machine will still operate
if error persists, replace.
Err18
Squeegee lift actuator overload
Check for binding of squeegee lift linkage and excessive weight of
squeegee. Repair.
Err19
Squeegee lift actuator severe overload
Check for binding or frozen squeegee lift linkage and excessive weight
on squeegee. 2. Check for short circuit in wiring or actuator motor.
Repair or replace.
Err20
Squeegee lift actuator circuit open (**)
1. Check for disconnected actuator wiring, open in wiring or defective
actuator motor, Repair or replace. 2. Controller failure (replace).
Err24
Vacuum motor overload
1. Check for debris in vac motor. 2. Worn carbon brushes. 3. Defective
motor bearings. Repair or replace.
Err25
Vacuum motor severe overload
Check for short circuit in vac motor or wiring.
Err26
Vacuum motor circuit open (**)
1. Check for disconnected vacuum motor wiring, open in wiring,
defective vacuum motor and vac contactor failure. Repair or replace.
2. Controller failure (replace).
Err27
Vacuum contactor contacts shorted
Check solenoid for welded contacts (continuity test). If welded replace
solenoid.
***
See the
Main Control Board Special Program Options
section to activate the Brush Type Selection function.
MAIN CONTROLLER ERROR CODES (CONTINUED)
revised 12/02