4
Applications
84
Total Station NPL-322 Instruction Manual
5.
Enter the second point on the vertical plane.
Press
[ENT]
.
Once the plane is defined, the calculated Sta and dZ
values are updated as you move the telescope. No
distance measurement is required.
Using
[DSP]
to switch between display screens
Press
[DSP]
to switch between the plane display screens. The following screens are
available:
Every time you press
[DSP]
, the next screen appears. If you press
[DSP]
in the last screen
(PLN3), the PLN1 screen appears.
To record the point, press
[ENT]
on any screen (V-
PLN1/3 to V-PLN3/3).
Enter PT and CD. Then press
[ENT]
.
Sample records
CO,Vertical Ref Plane Pt1:516-A1 Pt2:530
CO,Sta=68.021 dz=17.459
SS,30123-A48,1.5480,16.4020,40.4720,89.0730,14:22:47,
Sta
Horizontal distance from P1 to the target
point along the baseline
dZ
Vertical distance from P1 to the target
point
PLN1
PLN2
PLN3
Sta
dZ
X
Y
Z
HA
VA
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...