65
Applications
4
When you press
[ENT]
in the AZ field, both HA and AZ are reset to the value you
have entered.
Determining station elevation
1.
Press
[4]
or select
Remote BM
in the Stn Setup
menu.
2.
Enter the BM point and press
[ENT]
. When the
point is found, it appears briefly. The cursor then
moves to the HT field.
3.
Enter the HT and press
[ENT]
.
4.
Sight the BM point and press
[MSR1]
or
[MSR2]
.
5.
To take an F1/F2 measurement, press the
F2
softkey or flip the telescope to Face-2 after a
distance measurement.
The updated station coordinates are displayed.
You can change the HI in this screen.
6.
To record the updated STN, press
[ENT]
.
Even if both ST and BS are known points, this function does not calculate the backsight angle (AZ)
automatically. To calculate the AZ between two known points (ST and BS), use
Station Setup >
Known
. For more information, see
Setting up a station with known coordinates or azimuth, page 58
.
The
F2
softkey is not available on the NPL-322 5" single face model.
When the HI is changed, the Z coordinate is updated before the station is recorded.
You must complete a station setup before you use the Remote Benchmark function.
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...