4
Applications
64
Total Station NPL-322 Instruction Manual
Advanced feature: Viewing and deleting a measurement in resection
To check the measurements to each known point, press
the
View
softkey on the calculated STN (sigma or
coordinate) screen.
To delete a measurement (because of large sigma values, for example), highlight the
measurement data or display the detail screen for the measurement. Then press the
DEL
softkey. The STN coordinates are automatically recalculated.
To continue resection observations, press the
Add
softkey. The input screen for the next PT appears.
Setting up the station quickly without coordinates
The station point (ST) in this function defaults to a new point number. For the new
point, MP (0, 0, 0) is stored as the coordinates. When the ST is manually changed to a
known point name, the station is set up on the coordinates of the known point.
1.
To enter Quick Station setup, press
[3]
or select
Quick
in the Stn Setup menu.
2.
No default PT is assigned to the BS. Leave this
field blank, or enter a BS point name.
3.
The backsight azimuth (AZ) defaults to zero, but
you can change this.
4.
To complete the station setup, sight the BS and
press
[ENT]
.
dHA
Distributed HA errors in each direction
dVD
VD errors between measured distance and calculated
distance
dHD
HD errors between measured distance and
calculated distance
ST
Station point (defaults to the last recorded PT + 1, or
ST + 1, depending on the Split ST setting)
HI
Height of instrument
BS
Backsight point (blank)
AZ
Backsight azimuth (defaults to zero)
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...