5
Menu Key
120
Total Station NPL-322 Instruction Manual
CP records are shots taken in the Angle or Repeat menus, or in the BMS. For more
information, see
Recording a foresight point after repeat angle measurement, page 56
,
and
Recording data from any observation screen, page 86
.
F1 and F2 records are Face-1 and Face-2 measurements.
When the Store DB setting is set to RAW+XYZ, press
[DSP]
to switch between the first
screen (showing HA, VA, SD, PT, and HT) and the second screen (showing X, Y, Z,
PT, and CD).
Coordinates are not available in F1 or F2 records.
When you take more than one measurement to the same point and choose to
overwrite the XYZ data, the old raw record becomes raw data only. As a result, only
one SS(RAW) record keeps its corresponding SS(XYZ) record. Other SS(RAW)
records to the same point no longer have coordinates available.
ST records
ST (station) records contain ST, HI, BS, and AZ fields.
Press
[DSP]
to switch between the first screen (showing ST, HI, BS, and AZ) and the
second screen (showing X, Y, Z, PT, and CD).
When you assign a new ST point name in
MENU > Stn Setup > Quick
, the
coordinates of the station is recorded as (0, 0, 0).
SO records
SO records are stakeout shots. These are shots recorded in stakeout functions.
When the Store DB setting is set to RAW+XYZ, press
[DSP]
to switch between the first
screen (showing HA, VA, SD, PT, and HT), the second screen (showing X, Y, Z, PT,
and CD), and the third screen (showing dX, dY, dZ, PT, and CD).
The dX, dY, and dZ fields store the difference between the stakeout shot’s actual
position and its planned position. These fields are downloaded as comment records in
Nikon RAW format.
CO records
A CO record is a comment added to the job from the system.
For example, when you change the Stn-Z using the
Remote Benchmark function, or you reset the
horizontal angle using the BSCheck function, the
system writes a comment record.
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...