410-00352
EN
PM410-00352R20383
5
Start programming the position. If necessary,
correct the position of the roller shutter/blind
with a programmed transmitter
> 1,6 s
LED 3TB and
LED1 or LED2 flash
Display: centre line flashes
6
Current position of the roller shutter/blind is
saved. When all the LEDs go out, the receiver is
ready for operation again
> 1,6 s
LED 3TB + 2TB
light up
4.5. Deleting the transmitter
In delete mode, individual transmitters can be deleted from the memory of an output.
Note: If the transmitter is programmed in several outputs, it must be deleted individually from each output as
necessary. If an attempt is made to delete a transmitter that is not programmed into the selected output, the
LEDs flash quickly and the receiver remains in delete mode.
Step Operation
Button to press
Display
1
Start the programming mode in 3- or 2-button
mode
1x briefly
or
2x briefly
LED 3TB flashes
LED 2TB flashes
2
Select delete mode L
repeatedly
L
3
Select output. Only one output can be selected.
Output can be changed as often as required
or
LED 1 or LED 2 + LED
xTB flash
4
Start delete mode
> 1,6 s
LED 3TB + 2TB and LED 1
or LED 2 flash quickly
5
Delete transmitter from the selected output
Transmitter
button x
1x briefly
LED 3TB + 2TB and LED 1
or LED 2 light up.
When all the LEDs go out,
the receiver is ready for
operation
4.6. Deleting all transmission codes (Reset)
All programmed transmitters are deleted and all switching times for the respective output are reset. A reset must
be performed individually for each output.
Step Operation
Button to press
Display
1
Start the programming mode in 3- or 2-button
mode
1x briefly
or
2x briefly
LED 3TB flashes
LED 2TB flashes
2
Select delete mode L
repeatedly
L
3
Select output. Only one output can be selected.
Output can be changed as often as required
or
LED 1 or LED 2 + LED
xTB flash
4
Start delete mode
> 1,6 s
LED 3TB + 2TB and LED 1
or LED 2 flash quickly
5
Delete all transmitters from the selected output
and reset all times to the factory default settings
until
> 1,6 s
LED 3TB + 2TB and LED 1
or LED 2 light up.
When all the LEDs go out,
the receiver is ready for
operation
5. SPECIFICATIONS
Frequency
868.30 MHz
Modulation
FSK
Protocol
Easywave
Power supply
230 V AC 50 Hz
Output
2 potential-loaded outputs each with 2 relay contacts
Power consumption
0.4 W standby
max. 1 W without load
Max. contact load
• ohmic load cos =1
• inductive load cos =0,8
6.0 A / 1,500 VA
4.8 A / 1,200 VA
Protection degree
IP20
Operating temperature
-20 °C to +45 °C
Dimensions (W/L/H)
34.5 / 89.6 / 62.8 mm
Weight