42
www.hysecurity.com
SLIDESMART CNX 15 BASIC MANUAL
MX4779 REV. A ©2019
APPENDIX A - VEHICLE DETECTOR LOOPS
B
ENTER
EXIT
OUTSIDE
OBSTRUCTION
LOOP
A
ACCESS CONTROL DEVICE
(Card reader, etc.)
Vehicle Detectors and Loop Layout for Slide Gates
PUBLIC SIDE
This layout illustrates a
bi-direconal traffic system with
controlled access entry (card
reader, radio control, etc.) and a
free exit gate. The gate’s closure
me is determined by the number
of seconds entered in the
CLOSE TIMER display found in the
User Menu. The mer to close
starts when all loops are clear.
The mer is adjustable from
1 to 99 seconds.
For a enter only system,
the FREE EXIT loop is not needed.
For a enter only system,
the FREE EXIT loop is not needed.
SECURE SIDE
C
D
E
FREE EXIT
DIMENSIONS
A
= 6 to 20 (2 to 6m)
B
= 6 to 8 (2m to 243cm)
C
= Maintain 4 (122cm)
D
= Maintain 5 (152cm) between loop
and edge of roadway. No vehicle can pass
through such a small area and escape detecon.
E
= Located for convenience of use.
INSIDE
OBSTRUCTION
LOOP