MX4779 REV. A ©2019
SLIDESMART CNX 15 BASIC MANUAL
www.hysecurity.com
13
NEW INSTALLATION
1. Make sure the pad is completely level before
installation.
2. Determine the location of the operator from the
3. Refer to Figure 4 for minimum dimensions for a
new concrete pad. Refer to Figure 6 for conduit
and earth ground requirements.
4. Mark the anchor hole positions on the concrete
5. Remove the operator and drill holes for four 1/2
inch UNC x 3-1/2 inch wedge style anchors.
6. Install the anchor bolts, mount the operator on
the bolts, put a heavy duty flat washer on each
bolt, and tighten the anchor-bolt nuts.
7. Bury the earth ground rod and connect earth
ground wire to the chassis ground lug.
RETROFIT INSTALLATION
1. Remove any existing operator and anchor bolts.
2. Check the level of the concrete pad and level it if
needed.
3. Position the new SlideSmart CNX operator
around the conduit.
4. Mark the new anchor locations (Figure 4).
5. Remove the operator and drill holes for four 1/2
inch UNC x 3-1/2 inch wedge style anchors.
6. Install the anchor bolts, mount the operator on
the bolts, put a heavy duty flat washer on each
bolt, and tighten the anchor-bolt nuts.
7. Route the earth ground wire and connect it to
the earth ground lug.
OPERATOR POSITION