32
www.hysecurity.com
SLIDESMART CNX 15 BASIC MANUAL
MX4779 REV. A ©2019
RELAY OUTPUTS - BASIC
10 11
9
USER RELAY
OUTPUTS
RELAY 1 – 3 LOGIC
0 DISABLED
1 CLOSE LIMIT
2 CLOSE PULSE
3 OPEN LIMIT
4 OPEN PULSE
5 WARN B4 OP
6 GATE LOCK
7 FORCE OPEN
8 OPEN 2LONG
9 SAFE MODE
10 ENTRAPMENT
11 TAILGATER
12 OUTSIDE LOOP
13 LOITERING
14 NEAR LIMIT
15 ALERT/FAULT
16 MOTOR RUNNING
17 AC POWER LOSS
18 LOW BATTERY
19 FLASHER
20 EXIT LOOP
21 INSIDE LOOP
22 CENTER LOOP
23 PRISON LOCK
24 PARTIAL OPEN
25 BATTERY OK
26 EXIT PULSE
27 NOT OP AC
28 FLASH AC
29 ARM ENTRY
30 ARM EXIT
31 RESET TKT
32 BACKOFF
33 TRANS IN
34 TRANS OUT
35 TENANT IN
36 TENANT OUT
37 SPEC IN
38 SPEC OUT
39 UNK IN
40 UNK OUT
41 TEST OPEN
42 AMR BREAK
43 WARN THRU
44 POL PULSE
45 OUTS CLOSE
46 TIMER OPEN
47 OXI ACCESSORY
48 OXI ACC/-MIN
0 DISABLED –
48 OXI ACC/-MIN
RELAY 4 – 11 ARE VISIBLE AND CONFIGURABLE ONLY WITH OPTIONAL
I/O EXPANSION MODULE WHICH CONNECTS VIA TWISTED SHIELDED PAIRS
COMMUNICATION CABLE FROM HS-2 ON THE SMARTCNX CONTROLLER TO
HS-1 ON THE EXPANSION MODULE
RELAY 4 – 11 LOGIC
The three relays on the SmartCNX Controller are
configurable to perform a wide range of options
for integration with external devices. For more
information, see Advanced Manual.
1. Install the relay controlled device according to
the manufacturer's instructions.
2. Route the relay wires to the SmartCNX Controller
3. Install the relay wires in the appropriate relay
port: mechanical (Relay 1) or solid state (Relay 2
4. Press MENU on the SmartCNX Controller.
5.
Press the UP or DOWN arrow to navigate to
USER RELAY OUTPUTS, press SELECT,
6.
Press the UP or DOWN arrow to navigate to
RELAY LOGIC, press SELECT.
7.
Press the UP or DOWN arrow to highlight the
appropriate setting, press SELECT.
8. Press BACK until the SmartCNX controller resets
and operator status displays.
Figure 34.
Route Relay Wires
Figure 35. Relay Ports
z
Accessory power limited to 2A at 24VDC.
z
Relay capacity: (1) Mechanical 20A max at