• Start Close after photo (0x7a)
This parameter determines which safety device restarts closing after a trip. You can choose between:
- Photocells and Loop (0x40). Default setting
- Loop only (0x41).
- Photocells only (0x42).
• wait time (0x85)
This parameter is expressed in seconds and can be set with a value from 0 to 250 sec.; the factory setting is 5 sec. This function enables programming on
the Control unit of the required wait time to pass between the end of an Opening manoeuvre and the start of a Closing manoeuvre.
Always close (0x87)
•
active (0x88)
This parameter is ON/OFF; the factory setting is “OFF”. This function is useful in the event of a power failure, even brief. During an Opening manoeuvre if the
automation shuts down due to a power failure and the function is active (ON), the Closure manoeuvre is performed normally when power is restored. On
the contrary, if the function is not active (OFF), the automation remains stationary when power is restored.
Note
– For reasons of safety, when the function is
active, the Closure manoeuvre is preceded by a wait time as programmed in the function “pre-flash time”.
•
mode (0x8a)
This parameter is factory set on the mode “always close”. The function has 2 operating modes:
standard
– For this mode, refer to the function “active” under the item “always close”;
save automatic closure
– With this mode active, when power is restored after a power failure, two results are possible:
a)
execution of automatic closure,
observing the time as programmed in the function “pre-flashing time”, if the timeout interval of this time was in progress at the time of the power failure; b)
execution of closure manoeuvre if the automatic closure was in progress at the time of the power failure and the manoeuvre had not been completed.
Note
– If the automatic closure manoeuvre was cancelled before the power failure (for example, by sending the Halt command), the Closure manoeuvre is
not performed when the power is restored.
•
wait time (0x89)
This parameter is expressed in seconds and can be set with a value from 0 to 20 sec.; the factory setting is 5 sec. This function enables programming on the
Control unit of the required wait time to pass between the end of an Opening manoeuvre and the start of a Closing manoeuvre.
Force (0x47)
•
opening force (0x4a)
This parameter can be set with a value from 10% to 100%; the factory setting depends on the version of barrier. The function adjusts the maximum force the
motor can absorb during an opening manoeuvre.
Important
– Setting this value too high can damage the gearmotor and overheat the control unit.
•
opening deceleration force (0x4d)
This parameter can be set with a value from 10% to 100%; the factory setting depends on the version of barrier. The function enables control of the maximum
force absorbed by the motor during the deceleration phase of an Opening manoeuvre.
Important
– Setting this value too high can damage the gearmotor
and overheat the control unit.
•
closing force (0x4b)
This parameter can be set with a value from 10% to 100%; the factory setting depends on the version of barrier. The function enables control of the force
absorbed by the motor during a Closing manoeuvre.
Important
– Setting this value too high can damage the gearmotor and overheat the control unit.
•
closing deceleration force (0x4d)
This parameter can be set with a value from 10% to 100%; the factory setting depends on the version of barrier. The function enables control of the maximum
force absorbed by the motor during the deceleration phase of a Closing manoeuvre.
Important
– Setting this value too high can damage the gearmotor and
overheat the control unit.
•
action time (0x37)
This parameters sets the action time when the set level of force is exceeded. It is expressed in multiples of 30ms and can be set from 6 (=180ms) to 32
(=960ms). Increasing this setting increases the action time of the amperometric obstacle detection function.
Sensitivity (0x38)
The sensitivity parameter is linked with the encoder and, together with the force function, is used to limit the obstacle detection time following an impact. The
greater the sensitivity, the shorter the time between encoder pulses. The lower the sensitivity, the longer the time between encoder pulses.
•
opening sensitivity (0x3a)
This parameter takes values from 0 to 200, and is used during opening manoeuvres; the factory setting depends on the version.
Important
– a too high
setting can cause false positives due to the oscillation of the barrier itself.
•
opening deceleration sensitivity (0x3d)
This parameter takes values from 0 to 200, and is used during the opening deceleration cycle; the factory setting depends on the version.
Important
– a too
high setting can cause false positives due to the oscillation of the barrier itself.
•
closing sensitivity (0x3b)
This parameter takes values from 0 to 200, and is used during closing manoeuvres; the factory setting depends on the version.
Important
– a too high setting
can cause false positives due to the oscillation of the barrier itself.
•
closing deceleration sensitivity (0x3d)
This parameter takes values from 0 to 200, and is used during the closing deceleration cycle; the factory setting depends on the version.
Important
– a too
high setting can cause false positives due to the oscillation of the barrier itself.
Exclusion position (0xa4)
This parameter is expressed in seconds and can be set with a value from 0 to 250 seconds; the factory setting is 5 seconds.
Note
– The value “0” is consid-
ered to be the fully closed position of the automation
. This function enables the programming of the maximum limit, over which the control unit automatically
disables the inversion manoeuvres envisaged in the obstacle detection functions, if the latter are active.
Speed (0x40)
•
opening speed (0x42)
This parameter can be set with a value from 15% to 100%; the factory setting depends on the version. The function enables programming of the required
motor speed during an Opening manoeuvre.
Important
– This parameter also affects the impact forces.
•
opening deceleration speed (0x45)
This parameter can be set with a value from 5% to 100%; the factory setting depends on the version. The function enables programming of the required
motor speed during the deceleration phase of an opening manoeuvre.
Important