background image

flashing light

This function enables the flasher to indicate execution of a manoeuvre in progress with flashes at regular intervals 
(0,5 sec. ON; 0,5 sec. OFF).
Output active 12 Vdc / max 21 W

Flasher 1

This function enables the flasher to flash constantly at regular intervals (0.5 sec ON; 0,5 sec. OFF) both during a 
manoeuvre and when the pole is stationary.
Output active 24 V DC / max 10 W

24V flasher

This  function  enables  the  flashing  light  to  indicate  execution  of  a  manoeuvre  in  progress  with  flashes  at  regular 
intervals (0.5 sec ON, 0.5 sec OFF).
Output active 24 V DC / max 10 W

courtesy light

This function type is ON/OFF. Important – For safety reasons, as the light is not controlled by a timer, use of an 
adequate light, able to withstand the heat of the light emitted, is recommended.
Output active 24 V DC / max 10 W

Always on

This function enables the indicator light to remain constantly lit both during a manoeuvre and when the pole is 
stationary.
Output active 24 V DC / max 10 W

electric lock 1

With this function programmed, when an Opening manoeuvre is performed the electric lock is activated for a time 
as set in the function “electric lock time – output configuration”.
Output active 24 V DC / max 10 W

electric block 1

With this function programmed, when an Opening manoeuvre is performed the electric lock is activated for a time 
as set in the function “electric lock time – output configuration”.
Output active 24 V DC / max 10 W

suction cup 1

With this function programmed, the suction cup is activated when the application is in the maximum Closing posi-
tion. Note – The suction cup is disabled in all other situations. When the suction cup is disabled, before an Opening 
manoeuvre is started, the time interval as programmed in the function “suction cup time – output configuration” is 
activated, which delays the start of the manoeuvre.
Output active 24 V DC / max 10 W

red traffic light

This function indicates activity of the application during the phases of a Closing manoeuvre.
slow flashing = execution of Closing manoeuvre;
light permanently on = application in maximum Closing position;
light off = application in other positions.
Output active 24 V DC / max 10 W

green traffic light

This function indicates activity of the application during the phases of an Opening manoeuvre.
slow flashing = execution of Opening manoeuvre;
light permanently on = application in maximum Opening position;
light off = application in other positions.
Output active 24 V DC / max 10 W

radio channel no.1

If this radio channel is set for the configuration of output 1 (flash), this channel is activated when a command is set 
with the transmitter. It is useful if installing external devices (for example, an auxiliary light) in the same system to be 
controlled with a single transmitter. CAUTION – If this channel is not free on the control unit's receiver, due to having 
been previously memorised with a command, when the channel is activated by the transmitter, the control unit only 
activates the programmed output, and ignores the motor command.
Output active 24 V DC / max 10 W

radio channel no.2

If this radio channel is set for the configuration of output 1 (flash), this channel is activated when a command is 
set with the transmitter. This mode is useful if installing external devices (for example, an auxiliary light) in the same 
system to be controlled with a single transmitter. CAUTION – If this channel is not free on the control unit's receiver, 
due to having been previously memorised with a command, when the channel is activated by the transmitter, the 
control unit only activates the programmed output, and ignores the motor command.
Output active 24 V DC / max 10 W

radio channel no.3

If this radio channel is set for the configuration of output 1 (flash), this channel is activated when a command is 
set with the transmitter. This mode is useful if installing external devices (for example, an auxiliary light) in the same 
system to be controlled with a single transmitter. CAUTION – If this channel is not free on the control unit's receiver, 
due to having been previously memorised with a command, when the channel is activated by the transmitter, the 
control unit only activates the programmed output, and ignores the motor command.
Output active 24 V DC / max 10 W

radio channel no.4

If this radio channel is set for the configuration of output 1 (flash), this channel is activated when a command is 
set with the transmitter. This mode is useful if installing external devices (for example, an auxiliary light) in the same 
system to be controlled with a single transmitter. CAUTION – If this channel is not free on the control unit's receiver, 
due to having been previously memorised with a command, when the channel is activated by the transmitter, the 
control unit only activates the programmed output, and ignores the motor command.
Output active 24 V DC / max 10 W

Loop1

This output copies the status of the command coming from Loop1, per the current settings.
Output active 24 V DC / max 10 W

Loop2

This output copies the status of the command coming from Loop2, per the current settings.
Output active 24 V DC / max 10 W

output 2

This output can be set to one fo the functions described in Table 3, including those described below

Buzzer/Siren (0x1d)

This function activates the output (siren) when the amperometric force limiter trips twice during a given manoeuvre. 
The barrier locks and accepts no further commands. The siren sounds for 5 minutes; it then deactivates but the 
barrier stays locked.
To release the barrier press the control unit’s STOP button, or actuate the device connected to the control unit’s 
STOP input.
Output active 24 V DC / max 10W

Summary of Contents for LBar

Page 1: ...Programmable functions using the Oview programmer MBar LBar STF XBA3 Rev00 Firmware XB02a XU01 XF01 ...

Page 2: ... a programming session followed by the log out procedure on completion of the programming procedure Note the log out procedure enables the user to prevent access by unauthorised personnel by re activating the existing password Caution In programming the password on multiple devices for example on the Oview control unit receiver etc it is advisable to use the same password for all devices including...

Page 3: ... at the end of the wait time programmed in the function pause time If the function is not active OFF the Control unit operation mode is semiautomatic Pause time 0x81 This parameter is expressed in seconds and can be set with a value from 0 to 250 sec the factory setting is 20 sec This function enables programming on the Control unit of the required wait time which must pass between the end of an O...

Page 4: ...n of barrier The function enables control of the force absorbed by the motor during a Closing manoeuvre Important Setting this value too high can damage the gearmotor and overheat the control unit closing deceleration force 0x4d This parameter can be set with a value from 10 to 100 the factory setting depends on the version of barrier The function enables control of the maximum force absorbed by t...

Page 5: ...n be set with a value from 0 to 10 sec the factory setting is 3 sec This function programs the flashing time which indicates the imminent start of a Closing manoeuvre it is associated with the pre flashing function Stand by 0x8b active 0x8c This parameter is ON OFF the factory setting is OFF When this function is set to ON automation power consumption can be reduced mode 0x8e The function has 3 op...

Page 6: ...ration opening mode This command is factory assigned to Input 2 in mode open When this command is sent the control unit activates the ap plication to complete the Opening manoeuvre until the position is reached as set in the function opening Control unit func tions installation positions opening Input configured as normally open Close Closure Program the desired mode from those listed in table 1 B...

Page 7: ...de apartment block 1 open When this command is sent the control unit activates the ap plication to perform the opening manoeuvre only until the limit switch is reached Note This command is useful when using control photocells or a magnetic detector loop Input configured as normally open Photo Safety function Photo Program the desired mode from those listed in Table 1 F command configuration photo ...

Page 8: ...iation of the metal body required to start a manoeuvre Note set a high sensitivity to detect small metal bodies set a low sensitivity to detect large metal bodies Loop activation 0xe7 This parameter type is ON OFF the factory setting is ON Activating the loop means that the barrier will react as programmed when it is tripped If the function is DEACTIVATED the status of the loop is available if one...

Page 9: ...er command is sent after this one the application executes the Closing manoeuvre with the same sequence Apartment block 2 step by step This executes the sequence close stop partial open 1 partial open 1 until the position is reached as pro grammed in the function Partial Open 1 Note If another command is sent after this one the application executes the Closing manoeuvre with the same sequence Impo...

Page 10: ...lication to perform a brief inversion in the opposite direction Closing Caution During execution of the Opening manoeuvre this command is ignored Stop When the control unit receives the command it stops the Opening manoeuvre in progress Caution During execu tion of the Opening manoeuvre this command is ignored temporary stop When the control unit receives the command it stops the Closing manoeuvre...

Page 11: ...er TABLE 2 OUTPUT CONFIGURATION FUNCTION DESCRIPTION sca 0x01 The programmed light indicates the operating status of the control unit light off application in maximum Closing position slow flashing application Opening manoeuvre execution phase quick flashing application Closing manoeuvre execution phase light permanently on application in maximum Opening position SCA1 0x14 The programmed light ind...

Page 12: ...nnel is not free on the control unit s receiver due to having been previously memorised with a command when the chan nel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Radio channel 4 0x12 When a transmitter sends a command this output is activated This mode is useful if installing external devices for example an auxiliary light ...

Page 13: ...tem to be controlled with a single transmitter CAUTION If this channel is not free on the control unit s receiver due to having been previously memorised with a command when the channel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Output active 24 V DC max 10 W radio channel no 2 If this radio channel is set for the configurati...

Page 14: ... to occupation by a metal body Loop2 Indicates when the loop is activated due to occupation by a metal body BOARD KEYS no 1 Indicates when key 1 is pressed OPEN on the control unit no 2 Indicates when key 2 is pressed STOP on the control unit no 3 Indicates when key 3 is pressed CLOSE on the control unit DIRECTION SELECTION Indicates the status of the direction selector for a manoeuvre INPUT STATU...

Page 15: ...ata is useful to understand whether the encoder is in an overtravel position i e outside the operating zone of the absolute encoder bluebus device diagnostics This function displays the type operating status and configuration of devices connected ot the Bluebus output These parameters are described in Table 6 TABLE 6 DIAGNOSTICS of bluebus devices PARAMETER DESCRIPTION Bluebus PHOTOCELLS PHOTO Ind...

Page 16: ...s required after performing mainte nance on the automation ADVANCED FUNCTIONS event log This function enables the display of the events generated or received by the control unit An event is a condition which changes the operating status of the control unit such as activation of an input end of a manoeuvre photocell or stop input tripped etc This section displays the date and type of an event firmw...

Reviews: