CBOX936
INSTALLATION AND PROGRAMMING MANUAL
36
P1 AND P2 INPUTS (P1 / P2)
The P1 and P2 inputs may be used to connect 300 Hz pulse safety devices. If these inputs are set as pulse safety
(value 1) or pulse entrapment (value 2), the control board will not operate if devices are not found at these
inputs. If not used or used for a radio receiver, radio remote, a keypad, or similar devices, set value to 0. Values
are as follows:
• 0 = Step By Step (Default).
• 1 = Pulse Safety (if the photo eye is obstructed in the close direction, the operator will stop and reverse to
full open).
• 2 = Pulse Entrapment (if the photo eye is obstructed in the open or close direction, the operator will stop
and reverse direction of travel for 2 seconds).
NOTE:
300 Hz pulse safety devices may be used either instead of the BlueBUS photo eyes or in conjunction
with them.
SOLENOID LOCK OUTPUT CONNECTOR
SOLENOID LOCK
Solenoid Lock allows a solenoid lock to be engaged after the gate closes, but also introduces a slight delay (1
second) in gate open and closing to allow solenoid lock to engage and disengage. Values are as follows:
• 0 = OFF (default)
• 1 = ON
P1 INPUT
P2 INPUT
IMAGE 21-2:
P1 AND P2 INPUT LOCATIONS