CBOX936
INSTALLATION AND PROGRAMMING MANUAL
8
GENERAL GATE CONSTRUCTION REQUIREMENTS:
G
ate
t
ypes
Gates shall be constructed in accordance with the
provisions given for the appropriate gate type listed. Refer
to ASTM F2200 for additional gate types.
D
etacheD
G
ates
Gates shall be designed, constructed and installed to not
fall over more than 45 degrees from the vertical plane,
when a gate is detached from the supporting hardware.
G
ate
B
ottom
e
DGe
Gates shall have smooth bottom edges, with vertical
bottom edged protrusions not exceeding 0.50 inch (12.7
mm) when other than the exceptions listed ASTM F2200.
B
arBeD
W
ire
/t
ape
h
eiGht
The minimum height for barbed wire shall not be less than
6 ft. (1.83 m) above grade. The minimum height for barbed
tape shall not be less than 8 ft. (2.44 m) above grade.
e
xistinG
G
ate
L
atches
An existing gate latch shall be disabled when a manually
operated gate is retrofitted
G
ate
L
atch
r
estrictions
A gate latch shall not be installed on an automatically
operated gate.
G
ate
p
rotrusions
Protrusions shall not be permitted on any gate. Consult
ASTM F2200 for exceptions
.
G
ravity
anD
G
ate
m
ovement
Gates shall be designed, constructed and installed such
that their movement shall not be initiated by gravity when
an automatic operator is disconnected.
p
eDestrian
G
ates
For pedestrian access in the vicinity of an automated
vehicular gate, a separate pedestrian gate shall be provided.
The pedestrian gate shall be installed in a location such
that a pedestrian shall not come in contact with a moving
vehicular access gate. A pedestrian gate shall not be
incorporated into an automated vehicular gate panel.
u
pGraDinG
n
on
-a
utomatic
Gates
Any non-automated gate that is to be automated shall be
upgraded to conform to the provisions of this specification.
p
eDestrian
anD
non
-a
utomatic
G
ates
This specification shall not apply to gates generally used
for pedestrian access and to vehicular gates not to be
automated.
u
pGraDinG
e
xistinG
a
utomateD
G
ates
Any existing automated gate, when the operator requires
replacement, shall be upgraded to conform to the provisions
of this specification in effect at that time.
VEHICULAR HORIZONTAL SLIDE GATE REQUIREMENTS:
c
Lass
i, ii
anD
iii v
ehicuLar
h
orizontaL
s
LiDe
G
ates
:
The following provisions shall apply to Class I, Class II and Class
III vehicular horizontal slide gates:
Exposed Rollers
All weight bearing exposed rollers 8 feet (2.44 m), or less, above
grade shall be guarded or covered
Guarding or Screening Gate Openings
All openings shall be designed, guarded, or screened from
the bottom of the gate to the top of the gate or a minimum
of 72 inch (1.83 m) above grade, whichever is less, to prevent
a 2 1/4 inch (57 mm) diameter sphere from passing through
the openings anywhere in the gate, and in that portion of the
adjacent fence that the gate covers in the open position. The
gate panel shall include the entire section of the moving gate,
including any back frame or counterbalance portion of the gate.
Gaps Between Gate Frames and Other Objects
A gap, measured in the horizontal plane parallel to the roadway,
between a fixed stationary object nearest the roadway (such
as a gate support post) and the gate frame when the gate is
in either the fully open position or the fully closed position,
shall not exceed 2 1/4 inch (57 mm). Exception: All other fixed
stationary objects greater than 16 inch (406 mm) from the gate
frame shall not be required to comply with this section.
Class I, Class II and Class III Gate Stops
Positive stops shall be required to limit travel to the designed
fully open and fully closed positions. These stops shall be
installed at either the top of the gate, or at the bottom of the
gate where such stops shall horizontally or vertically project
no more than is required to perform their intended function.
Gate Lateral Stability
All gates shall be designed with sufficient lateral stability to
assure that the gate will enter a receiver guide. Consult ASTM
F2200 for details on various gate panel types.
c
Lass
iv v
ehicuLar
h
orizontaL
s
LiDe
G
ates
:
The following provisions shall apply to Class IV vehicular
horizontal slide gates:
Guarded or Covered Rollers
All weight bearing exposed rollers 8 feet (2.44 m), or less, above
grade shall be guarded or covered.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]