AUTO CLOSE BUTTON
This option adjusts amount of time before gate automatically closes.
Press the AUTO CLOSE Button. “AC” momentarily appears in the display, followed by the default of either “0”
or the value last selected. Use the UP and DOWN buttons to choose 1 to 90 seconds, then press OK to accept
selection. Values are as follows:
• 0 = disabled (default)
• 1-90 = seconds until close begins
OPTIONS BUTTON
The OPTIONS button is used to access the following parameters:
• bb = Blue Bus Scanning
• bP = Bi-parting Gate
• rA = Run Alarm
• rc = Radio Channels
• Sb = Standby Mode
• Sc = Gate Synchronization
• SL = Solenoid Lock
• P1 = Program Input 1
• P2 = Program Input 2
USING THE OPTIONS BUTTON
1.
Press OPTION button and “bb” will appear in display.
2. After pressing the OPTION button, each press of the DOWN button accesses each option in turn.
3. Press OK while an option is displayed to enter the parameter values for that option.
4.
Press the UP and DOWN buttons to scroll through the parameter values.
5. Press OK to accept the displayed value.
6.
Pressing the OK button after pressing the OPTION button will scan for the BlueBUS devices (bb will blink).
If devices are found, two dashes (--) will be displayed. If no devices are found then a flashing “E1” will be
displayed indicating a BlueBUS error. If there is a new BlueBUS configuration, then the LEARN button should
be pressed to re-learn the BlueBUS device configuration.
BI-PARTING GATE
Bi-parting Gate Enables overlapping dual gates to dovetail smoothly by creating a momentary delay for Motor
2 when opening and Motor 1 when closing.
Example:
If 03 is selected, in the OPEN direction Motor 2 will begin
to OPEN 3 seconds after Motor 1. In the CLOSE direction Motor 1 will begin to CLOSE 3 seconds after Motor 2.
• 0 = OFF (default)
• 1-5 = seconds delay between gates