CBOX936
INSTALLATION AND PROGRAMMING MANUAL
40
10.2 ACCESSORY INPUTS
Refer to FIGURE 10-1 and 10-2 for locations of the accessory inputs, which are described below.
AUXILIARY INPUT “A”; PROGRAM OPTION “P2”
This connector may be programmed (in OPTIONS) to accept 300 Hz pulse safety devices (safety or entrapment)
or by default used as a step-by-step input. This connector features 12VDC, 3A power output that may be used
to power external devices.
AUXILIARY INPUT “B”; STEP-BY-STEP
This inputs accepts devices that operate in a step-by-step mode.
OPEN INPUT
This input pin is a normally Open (NO) dry contact input. When shorted to ground (GND) it opens the gate to
the open limit.
CLOSE INPUT
This input pin is a Normally Open (NO) dry contact input. When shorted to ground (GND) it closes to gate to
the close limit.
STOP INPUT
This input pin is a Normally Closed (NC) dry contact input. In the absence of a 3-button station this input needs
to be shorted to ground (GND).
RESET INPUT
This input pin is a Normally Open (NO) dry contact input. When shorted to ground (GND) a hard shutdown
condition is reset.
EDGE INPUT
This input pin is a Normally Open (NO) dry contact input that stops a moving gate, momentarily reverses the
gate direction, then stops the gate. Typically used for edge sensors.
SAFETY (LOOP) INPUT
This input pin is a Normally Open (NO) dry contact input that stops a closing gate, then reopens the gate.
SHADOW (LOOP) INPUT
Normally Open (NO) dry contact input that prevents a fully closed gate from opening, prevents a fully open gate
from closing, stops and reverses open a closing gate and resets the auto-close timer (if activated).
FREE EXIT INPUT
Normally Open (NO) dry contact input that opens the gate from the closed position, reverses a closing gate
and holds the gate in the fully open position until the free exit input is deactivated.
UL INPUT
Normally Open (NO) dry contact input that stops a moving gate to prevent an entrapment condition. Two
successive activations of this input will create a hard shutdown condition. This condition requires a hard shutdown
reset (press RESET Button) before board will again function.
NOTES:
•
In Standby Mode the voltage is inactive. DO NOT use to power entry/exit devices.
•
A “Step-By-Step” input is a type of command that opens-stops-closes-stops the gate with each press of
a button or other activation.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]