Control
VVM 240
32
Menu 1.1 Time Period
The length of time is set here. The value is adjustable
between 5 and 60 minutes.
Menu 1.2 Max time for HW
The time (menu 1.1) that the hot water should be heat-
ed in each period is selected here. The value is
adjustable between 5 and 60 minutes.
Hot water temperature
Menu 1.3 Start temperature HW
The temperature when the heat pump starts to work
with the hot water heater is set here. This menu is only
used when VVM is docked. The value is adjustable
between 25 and 50 °C.
Menu 1.4 Stop temperature HW
The temperature when the heat pump/immersion
heater should stop heating the water is set here. The
value is adjustable between 30 and 80 °C.
Menu 1.6 Interval XHW
How often the hot water temperature is increased from
the normal level to the extra hot water level is shown
here. The value is adjustable between 0 and 90 days.
Extra hot water is shutoff when 0 is set. Extra hot
water starts when the value has been confirmed.
Menu 1.7 Next XHW action
Future increases to the extra hot water level are
shown here.
Menu 1.8 HW running time
How long hot water heating has been in progress is
shown here (accumulated).
Menu 1.9 Return
Pressing the enter button returns you to menu 1.0
3 0 m i n
T i m e P e r i o d
1 . 1
1 4 d a y s
I n t e r v a l X H W
1 . 6
H W r u n n i n g t i m e
1 . 8
R e t u r n
1 . 9
2 0 m i n
M a x t i m e f o r H W
1 . 2
4 5 ° C
S t a r t t e m p e r a t u r e H W
1 . 3
5 0 ° C
S t o p t e m p e r a t u r e H W
1 . 4
Menu 1.5 Stop temp XHW
The required stop temperature for extra hot water is
set here. The value is adjustable between 40 and
80 °C.
6 0 ° C
S t o p t e m p X H W
1 . 5
1 0 - 2 6 1 0 : 3 1
N e x t X H W a c t i o n
1 . 7
N
N
N
N
U
U
U
U