Hot water comfort
GENERAL
This function provides the opportunity to control additional
heat in the tank, mixing valve and hot water circulation.
ADDITIONAL HEAT IN TANK
If an immersion heater is installed in the tank, it can be per-
mitted to produce hot water at the same time as the heat
pump prioritises heating or cooling.
MIXING VALVE
A temperature sensor reads the temperature of the outgoing
hot water to the domestic hot water and adjusts the mixing
valve from the water heater until the set temperature has
been reached.
HOT WATER CIRCULATION (HWC)
One pump can be controlled for the circulation of the hot
water during selectable periods.
COMPATIBLE PRODUCTS
•
•
VVM 325
F1145
•
•
F1155
VVM 500
•
F1245
•
F1255
•
VVM 225
•
VVM 310
•
VVM 320
PIPE CONNECTIONS
MIXING VALVE
The mixer valve (QZ1-FQ3) must be placed on the outgoing
hot water line from the water heater according to the outline
diagram.
AB
A
B
•
Connect the incoming cold water via
the T-pipe to port B on the mixer valve
(closes at signal).
•
Connect the mixed water to the domest-
ic hot water taps from the mixer valve
to the common port AB (always open).
•
Connect the outgoing hot water from the water heater to
the mixer valve to port A (opens on signal)
TEMPERATURE SENSOR
•
Temperature sensor, outgoing hot water (QZ1-BT70), is
installed as close to the mixing valve (QZ1-FQ3) as pos-
sible.
LEK
LEK
E
Install the temperature sensor with cable ties with the heat
conducting paste and aluminium tape. Then insulate with
supplied insulation tape.
NOTE
To prevent interference, sensor cables to external
connections must not be laid close to high voltage
cables.
SYSTEM DIAGRAM
EXPLANATION
Caution
This is an outline diagram. Actual installations must
be planned according to applicable standards.
Hot water comfort
QZ1
AXC module
AA25
Hot water circulation pump
GP11
Mixer valve, hot water
FQ3
Trim valve
RN1
Non-return valve
RM1
Flow line sensor
BT70
Return line sensor, hot water
BT82
Temperature sensor, hot water heater
BT83
Water heater
CP1
Additional water heater
CP2
Heat pump
EB100
Temperature sensor, hot water
BT6
Temperature sensor, hot water top
BT7
OUTLINE DIAGRAM WITH ADDITIONAL WATER
HEATER,HWCANDELECTRONICMIXINGVALVE
-CP2
-CP1
-EB100
-QZ1-BT83
-EB100-BT7
-EB100-BT6
-QZ1-AA25
-QZ1-BT70
-QZ1-FQ3
-QZ1-GP11
-QZ1-RM1
-QZ1
-QZ1-RN1
-BT82
AXC 40 F-series | EN
56