CONNECTING COMMUNICATION
AXC 40 contains an accessory board (AA5) that connects
directly to the main product’s input board (terminal block
AA3-X4).
If several accessories are to be connected, or are already
installed, the boards are connected in series.
Because there can be different connections for accessories
with accessory board (AA5), you should always read the in-
structions in the manual for the accessory that is to be in-
stalled.
AA3-X4
15
14
13
A
B
GND
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
Main product
Accessory card 1
Accessory card 2
ON
1
2
3
4
5
6
7
8
-X9
-X2
24
20
21
22
23
15
16
17
18
19
10
11
12
13
14
5
6
7
8
9
1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
2
3
4
-X8
-X4
-X10
-X1
ON
1
2
3
4
5
6
7
8
-X9
-X2
24
20
21
22
23
15
16
17
18
19
10
11
12
13
14
5
6
7
8
9
1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
2
3
4
-X8
-X4
-X10
-X1
AA5-X4
AA5-X4
AA3-X4
F1245/F1255
VVM
225/310/320/325/500
AA3-X4
F1145/F1155
POWER CONNECTION
Connect the power supply cable to terminal block AA25-X1
as illustrated.
Tightening torque for earth cable: 0.5–0.6 Nm.
AA25-X1
N
L
Externt
ProduktNamn
2
1
AA25 External
AXC 40 F-series | EN
46
F