1. Remove the surround.
2. The pressure test taps are located on the valve. The taps are located in the gas valve front
face. The inlet is marked ‘
IN
’ and the outlet is marked ‘
OUT
’.
3. Loosen the set screw inside the tap with a screwdriver.
4. Connect a 1/4” (6 mm) rubber tube to the tap post and a manometer.
5. Verify that the readings obtained are within specs (as shown on the appliance rating plate)
6. Be sure to tighten the set screw inside the tap after you have finished taking pressure
readings.
7. Check for leaks.
VALVE INCLUDED IN THE 1060 SERIES (SIT SYSTEM)
CHECKING AND ADJUSTING PILOT
The flame should not have yellow tips but should engulf the
sensor. It can be adjusted by turning the screw marked “pilot”
on the control valve.