Series 1060
32
REMOTE CONTROL SETUP AND OPERATION (SKYTECH SYSTEM)
Configuration:
Continuous Pilot -
This fireplace has the capability to switch from Intermittent to standing pilot
Method #1: Using the hand held remote press
and
at the same time to activate standing pilot (#5 on display)
To revert to IPI repeat above procedure.
Method #2: Sliding the two position switch on the main module to Continuous pilot “ON”. Note* when the module is in this con-
figuration, the user will be unable to switch back to Intermittent Pilot ignition from the hand held remote.
Child Proof Safety Lock-out
This feature is activated by pressing
and
at the same time for more than 5 seconds.
When activated “CP” will appear in the Room Temperature window(#6) for approximately 5 seconds. “CP” will then be displayed
in the Room Temperature window whenever a transmitter button is pressed and no signal is transmitted.
To deactivate, repeat above procedure.
Manual / Remote Control:
(toggle switch, on/off operation)
To activate the toggle switch on the side of the surround, the Remote/Off (2 )position switch on the module needs to be in the
“OFF” position.
Note: when the module is in the “OFF” position, the hand held remote will have no control over the fireplace.
The fireplace will activate to last known setting and will have no flame adjustment.
Low Battery Indicator
( #4 will display)
Replace batteries soon.
Natural Gas / Propane Conversion:
(unit comes configured for NG from factory)
Press and hold “Learn” button on the module for 20 sec:
Single beep 1 seconds in length - Module is in LPG mode
Single beep 3 seconds in length - Module is in NG mode
This process only to be activated in conjunction with the complete conversion process. Only a licensed installer or service tech-
nician may install the conversion kit and switch the module to the appropriate fuel.
Summary of Contents for 1060 Series
Page 13: ...Series 1060 13 ELECTRICAL CONNECTIONS Figure 9 Figure 10 Figure 11 ...
Page 15: ...Series 1060 15 ELECTRICAL CONNECTIONS Figure 15 ...
Page 19: ...Series 1060 19 VALVE INCLUDED IN THE 1060 SERIES HONEYWELL SV950 SYSTEM Figure 19 ...
Page 21: ...Series 1060 21 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM future option ...
Page 23: ...Series 1060 23 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Page 24: ...Series 1060 24 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Page 25: ...Series 1060 25 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Page 26: ...Series 1060 26 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Page 27: ...Series 1060 27 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Page 43: ...Series 1060 43 NOTES ...
Page 44: ...Series 1060 44 NOTES ...