4.2 Sweep
WF1945B
4-29
(4) Set the START frequency
①
Use the
and
keys to produce the following display (START flashes).
1000.00000000 Hz
F-SWP:
3
FUNCTION
START
STOP
4
②
Press the
ENTER
key.
③
Set the frequency with the keypad or
MODIFY
dial.
For example, set to 100 Hz.
④
After setting, press the
EXIT
key once to release the start frequency setting mode.
(5) Set the STOP frequency
①
Use the
and
keys to produce the following display (STOP flashes).
10000.00000000 Hz
F-SWP:
3
FUNCTION START
STOP
4
②
Press the
ENTER
key.
③
Set the frequency with the keypad or
MODIFY
dial.
For example, set to 200 Hz.
④
After setting, press the
EXIT
key once to release the stop frequency setting mode.