3.3 Basic operation
WF1945B
3-24
Amplitude setting (
ENTRY
→
AMPTD
)
Amplitude (AMPTD) setting is described.
Operation:
The amplitude can be set by two methods.
(1) Keypad
Convenient when the amplitude has been determined beforehand.
For example, set 2 Vp-p as follows.
①
Press the
ENTRY
key, then the
AMPTD
key.
The following display is produced.
Amplitude
AMPTD 0.1000 Vpーp
1.000000000kHz O+0.0000V /OPEN
Frequency
DC offset
②
Press the
2
key, then the
ENTER
key.
To correct an entry, press the
BS
key before pressing
ENTER
key.
③
This completes setting, afterwards, press the
EXIT
key.
(2) Modify dial
The amplitude can be changed continuously.
①
Press the
ENTRY
key, then the
AMPTD
key.
②
Select the digit to be changed with the
and
keys.
③
Turn the
MODIFY
dial to set the flashing digit.
④
After setting, press the
EXIT
key to release the setting mode.
Other:
・
When the oscillation mode is DC, the amplitude cannot be set.
・
Units other than Vp-p can also be set.
“5.2 Units”, cf.
・
Can also be set by waveform high level and low level.
“5.1 Convenient Settings (
■
Amplitude and DC offset setting by high and low level)”, cf.
Summary of Contents for WF1945B
Page 2: ......
Page 3: ...DA00012505 002 WF1945B MULTIFUNCTION SYNTHESIZER Instruction Manual...
Page 4: ......
Page 8: ......
Page 20: ......
Page 30: ......
Page 62: ......
Page 100: ...4 2 Sweep 4 38 WF1945B Sweep value and Z MARKER SYNC X DRIVE outputs is approx 100 to 125 s...
Page 101: ...4 2 Sweep WF1945B 4 39...
Page 128: ......
Page 158: ......
Page 182: ......
Page 184: ......
Page 186: ......
Page 187: ......