5.2 Units
WF1945B
5-9
User-unit setting (
SYSTEM
→
USER-UNIT)
Operation for changing the units by using the user unit function is described.
For example, set for expressing frequency as rpm (revolutions per minute, e.g., engine rotation).
Operation:
(1)
Select setting type, for example, frequency
①
Press the
SYSTEM
key, then use the
and
keys to produce the following display (USER-
UNIT
flashes).
USER UNIT MENU
SYSTEM:
RANGE PRESET
USER-UNIT
4
②
Press the
ENTER
key, then use the
and
keys to produce the following display (TYPE
flashes).
FREQ
PERIOD AMPTD
4
USER UNIT:TYPE
NAME FORMULA
4
③
Again press the
ENTER
key, then use the
and
keys to produce the following display
(FREQ flashes).
FREQ
PERIOD AMPTD
4
USER UNIT:TYPE
NAME FORMULA
4
④
This selects the setting type to frequency. Press the
EXIT
key once to release the type select
mode.