Auto Charger
When enabled, this function automatically starts and stops the generator based on the configuration settings for Battery
Voltage, Max Run Time, Top Off Voltage, and Top Off Run Time. The generator will not automatically start if shore
power is present.
Exerciser
When enabled, this function will automatically run the generator based on the Exerciser Schedule settings. This function
will automatically start the generator regardless of the shore power status.
Climate Zone
When enabled, this function will cause the generator to automatically run based on the individual HVAC Zone demand.
The Climate Zone AGS function will automatically start and stop the generator. The generator will not automatically
start if shore power is present.
Screen 2
Page 2 of the AGS screen allows you to change the settings for Autocharger and Topoff.
SilverLeaf > Features 2 > Auto Genstart Configuration screen 2
Autocharger Start Volts (DC Voltage)
This setting determines the voltage level that will automatically start the generator. When the AGS is enabled and the
house battery voltage drops below this value for approximately two minutes, the generator will automatically start and
run until the charger goes into Float Mode or the Autocharger Max Run Time setting time has expired.
© 2014 Copyright Newmar Corporation. All rights reserved.
p.79
Summary of Contents for King Aire 2015
Page 1: ......
Page 2: ......
Page 4: ......
Page 24: ...Spartan Lightbar Message Center 2015 Newmar King Aire Diesel Bus 22...
Page 25: ...System Initialization Sequence 2015 Newmar King Aire Diesel Bus 23...
Page 26: ...Telltale Warning Light Information 2015 Newmar King Aire Diesel Bus 24...
Page 46: ...2015 Newmar King Aire Diesel Bus 44...
Page 146: ...SilverLeaf Floor Heat screen 2 2014 Copyright Newmar Corporation All rights reserved p 61...
Page 162: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 77...
Page 175: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 90...