![NewMar King Aire 2015 Manual Download Page 52](http://html1.mh-extra.com/html/newmar/king-aire-2015/king-aire-2015_manual_1679850052.webp)
General Instructions
IMPORTANT
The slide out room should be inspected for alignment every six (6) months. If alignment is necessary, have the
room adjusted.
IMPORTANT
The slide out room can be stopped at any time by releasing the slide out switch. If the slide out room stops
before reaching the full “OUT” or “IN” position, the slide out controller may need adjustment. To adjust the
slide out controller, turn the adjustment screw clockwise to increase the power and counter-clockwise to
decrease the power. Move the adjustment screw in small increments. Try moving the slide out room again.
Use caution. There is a potential for component or structural damage if the screw is adjusted too high. This
screw does not adjust the slide out room speed. It sets the amount of power required to move the room
against the mechanical stops.
Operating the Slide Out Room
Your unit is equipped with Power Locking Arms for the slide out rooms. Designed specifically for this
application, these mechanisms automatically “lock” the slide out rooms to the sidewalls of the RV when
the room is fully retracted, securing the room in place and providing a positive seal. The operation of the
locking mechanism is totally automatic, and begins when you press the button to extend or retract the
slide out room.
WARNING
Before extending the slide out, make certain that there is a minimum of five (5) feet of clear space on the slide
outside of the unit. Prior to extending the room, be sure to unlock the slide out locking arms. Make sure there
are no obstructions either inside or outside the unit that may interfere with the slide out extension. Tree
branches, bushes or telephone poles can cause extensive damage to the exterior of the unit.
To extend the room, make certain the coach is plugged into shore power or is under generator power, then
press and hold the slide out button. The power lock arms will retract into their housings, and the room
will begin to extend approximately 10 seconds after the voice begins. It will continue to run until it
reaches the end of its travel, or until you release the slide out switch.
To retract the room, press the slide out button as described above, holding it for the duration of room
travel. The room will retract, and at the end of its travel the slide out motor will stop, and the Power
Locking Arms will deploy, securing the room to the sidewall of the unit. Please note that you must hold
the slide out button down during this entire cycle.
The power locks require a minimum of 9 volts DC to operate. In the event of a loss of power, or if the
voltage dips below the minimum requirements, the locks will not extend or retract automatically.
For proper operation of the room and locks battery voltage must be maintained above the minimum
requirements. Also please note that there is a safety “lock out” system incorporated in the slide out
electronics that prevents the room from operating when the ignition key is “on”. The automatic locking
arms require no maintenance, and should be serviced as necessary only by a qualified technician.
2015 Newmar King Aire Diesel Bus 50
Summary of Contents for King Aire 2015
Page 1: ......
Page 2: ......
Page 4: ......
Page 24: ...Spartan Lightbar Message Center 2015 Newmar King Aire Diesel Bus 22...
Page 25: ...System Initialization Sequence 2015 Newmar King Aire Diesel Bus 23...
Page 26: ...Telltale Warning Light Information 2015 Newmar King Aire Diesel Bus 24...
Page 46: ...2015 Newmar King Aire Diesel Bus 44...
Page 146: ...SilverLeaf Floor Heat screen 2 2014 Copyright Newmar Corporation All rights reserved p 61...
Page 162: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 77...
Page 175: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 90...