Header
Hydraulic Alarms
Alarm
Description
Trigger
Conveyor
Hydraulic
Pressure Exceeds
Maximum
“Conveyor Hydraulic Pressure Exceeds
Maximum Operating Range.”
Conveyor hydraulic pressure exceeds
[Max Conveyor Hydraulics Pressure]
setting for a period of
fi
ve consecutive
seconds or longer.
System Hydraulic
Pressure Exceeds
Maximum
“System Hydraulic Pressure Exceeds
Maximum Operating Range.”
System hydraulic pressure exceeds [Max
System Hydraulics Pressure] setting for
a period of
fi
ve consecutive seconds or
longer.
Hydraulic Fluid
Level Low
“Hydraulic Fluid Level Low.”
Hydraulic
fl
uid level has fallen below
lowest level tank sensor.
Hydraulic Fluid
Temperature
Below Minimum
“Hydraulic Fluid Temperature Below
Minimum Operating Range.”
Hydraulic temperature is below 65°F
(18°C). Hydraulic
fl
uid too cold to
operate machine.
Hydraulic Fluid
Temperature
Exceeds
Maximum
“Hydraulic Fluid Temperature Exceeds
Maximum Operating Range.”
Hydraulic temperature exceeds
maximum operating range, greater than
or equal to 200°F (93°C).
Hydraulic Filter
Restriction
Detected
“Hydraulic Filter Restriction Detected.”
Hydraulic
fi
lter pressure is greater than
or equal to 25 psi for
fi
ve consecutive
seconds or longer.
Bin Sequencing Alarms
Alarm
Description
Trigger
Container
Advance
Moving to next container in the
sequence.
At the point when the [Container
Advance] criteria has been met.
End of Sequence
End of container sequence, do you
wish to start the sequence from the
beginning?
At the point the last container in the
sequence has met the [Container
Advance] criteria.
Chain Oiler Alarms
Alarm
Description
Trigger
Disable Spinners Manually disable or shut off the spinner
hydraulic circuit.
The point the user selects to run the
chain oiler routine.
Enable Spinners
Return the spinner hydraulic circuit to a
fi
eld ready condition.
The point the user exits the chain oiler
routine.
Conveyor
Lubrication
Required
Conveyor Chain Lubrication Is Required.
[Service Reminder On] setting is enabled
and [Service Reminder Interval] has
expired.
Controller Operations