- 134 -
www.New-Leader.com
(800) 363-1771
313974-AA-B
NL4500G4 TRIDENT
Header
Feed Gate Alarms
Alarm
Description
Trigger
Feed Gate Not
Calibrated
“Feed Gate must be calibrated prior to
operation.” + [Bin Name]
[Feed Gate Enable/Disable] is Enabled,
equipment pro
fi
le is active and feed
gate actuator has not been calibrated.
Feed Gate
Movement
“Feed Gate may move at this time.
Please keep clear of feed gate.” + [Bin
Name]
Upon user acknowledgement, dialog
is dismissed and warning
fl
ashes
on interval in the status bar until
corresponding feed gate calibration is
complete.
Feed Gate
Movement
During
Calibration
“Feed gate will move during calibration.
Please wait.”
Upon user acknowledgement, system
moves feed gate.
Feed Gate Not
Responding
“Feed Gate not responding.” + [Bin
Name]
Upon user acknowledgement, dialog
is dismissed. System allows product
application at current feed gate position.
Feed Gate
Sensor Outside
Expected
Operating Range
“Feed Gate sensor outside expected
operating range. Check sensor, and
related wiring.” + [Bin Name]
Upon user acknowledgement, dialog
is dismissed. System allows product
application at current feed gate position,
and feed gate control is disabled.
Feed Gate
Position Sensor
Error During
Calibration
Routine
“Lost or intermittent signal from feed
gate position sensor. Check sensor
and related wiring prior to continuing
calibration routine.”
Upon user acknowledgement,
calibration routine is exited.
No Feedback
from Position
Sensor
“No Feedback from Position Sensor.” +
[Bin Name]
Upon user acknowledgement, dialog
is dismissed. System allows product
application at current position.
Feed Gate out of
Position (Position
Sensor Reporting
Wrong Position)
“Feed Gate Out of Position.”
Upon user acknowledgement, dialog
is dismissed. System allows product
application at current position.
Feed Gate Circuit
Disabled
“Feed Gate Circuit Disabled.”
“Pressing acknowledge will enable and
allow feed gate to move. Do you wish to
proceed?”
Upon user acknowledgement, dialog is
dismissed. System sets feed gate circuit
to “Enabled”, Feed Gate movement
dialog is presented and system moves
feed gate to user de
fi
ned Feed Gate
Height setting.
Controller Operations