7 - MAINTENANCE
Air cleaner primary element
NOTE:
Replace the primary element after every 300 hours
of service. Extremely dusty conditions may require more
frequent service intervals.
1. Pull the primary element
(1)
from the canister. Clean
any loose dirt from the canister and inspect the end of
the canister for dirt which may prevent the new element
from sealing properly.
2. Install the new primary element by inserting it into the
canister and pushing on the end of the element until it
is seated against the canister.
NOTE:
If element is not inserted far enough into canister,
the end cap cannot be installed.
3. Place the end cap onto the canister body, push in on
end cap, and rotate clockwise. Make sure the end cap
is locked in place and not loose.
NOTICE:
Failure to obtain a good seal between elements
and the canister may cause major engine damage.
NHIL12CT00781AA
1
Fan belt tension
To adjust fan belt tension:
WARNING
Maintenance hazard!
The engine must be OFF when you loosen or tighten alternator mounting bolts.
Failure to comply could result in death or serious injury.
W1096A
1. Loosen the alternator mounting bolts
(1)
.
2. Pry the alternator away from the engine and tighten the
mounting bolts.
3. Recheck belt deflection
(A)
.
NHIL12CT00890AA
1
Wheels bolt/nut
See page
7-13
.
Roll Over Protective Structure (ROPS) - Maintenance and inspection
See
7-12
7-27
Summary of Contents for WORKMASTER 35
Page 10: ...1 GENERAL INFORMATION Proposition 65 BT09A213 1 1 4 ...
Page 16: ...1 GENERAL INFORMATION 1 10 ...
Page 46: ...2 SAFETY INFORMATION 2 30 ...
Page 98: ...4 OPERATING INSTRUCTIONS 4 30 ...
Page 167: ...9 SPECIFICATIONS NHIL12CT00862HA 1 9 7 ...
Page 168: ...9 SPECIFICATIONS 9 8 ...
Page 170: ...10 ACCESSORIES 10 2 ...
Page 171: ...11 FORMS AND DECLARATIONS 11 FORMS AND DECLARATIONS _11_ 11 1 ...
Page 172: ...11 FORMS AND DECLARATIONS 11 2 ...
Page 174: ...11 FORMS AND DECLARATIONS 11 4 ...
Page 176: ...11 FORMS AND DECLARATIONS 11 6 ...