Bearing
Housing
Cover
M1151-9444
Bearing Housing Cover O-Ring
P0280-6093
Motor Assembly (1.25L, 2.5L)
M1226-0700
Motor
Assembly
(5L)
M1226-0800
Units shipped before April 1, 1996 (Mfg. No. M1226-3004, -3005, -3006)
Heater, 400W, 100/120V Units
P0620-1330
S.S.R. (240D10), 10 Amp, 100-240 VAC Unit
P0400-3011
Heater, 400W, 220/240V Units
P0620-1331
Units shipped after April 1, 1996
Heater, 750W, 100/120 VAC Units
P0620-1320
S.S.R. (240D45), 45 Amp, 100-240 VAC Units
P0400-3151
S.S.R. (240D10), 10 Amp, 100-240 VAC Units
P0400-3011
Heater, 750W, 220/240V Units
P0620-1321
*NOTE: Ingold DO Probes must be used with DO Adapters.
O-RING
Description
1 1/4L
2 1/2L
5L
Head
Plate
P0280-8002
P0280-8062
P0280-8132
Bumper, Flat Gasket
M1151-9905 M1152-9904 M1155-9902
Knob
P0280-5322
Same
Same
DO
Port P0280-5932
Same
Same
DO Port (Ingold) Washer
M1016-0890 Same
Same
Teflon Washer (Ingold DO) P0100-9780 Same
Same
O-Ring (Ingold DO Probe)
P0280-9163 Same
Same
pH
P0280-5912
Same
Same
3/16"
Port
P0280-5302
Same
Same
1/4"
Port
P0280-5322
Same
Same
3/8"
Port
P0280-5342
Same
Same
1/2"
Port
P0280-5912
Same
Same
4.8 WARNING:
Do not attempt to change boards or electronic components unless you are a
qualified service technician. Integrated circuits are extremely susceptible
to damage from electrostatic discharge. Read and follow the precautions
in Section 4.9 before you begin.
4.9 ESD
PRECAUTIONS
1.
Do not remove components from their antistatic packaging until you are ready
to insert them into their sockets or install the board.
2.
Before handling components or boards, touch an unpainted portion of the
system unit chassis for a few seconds.
3.
Wear a wrist grounding strap, available from most electronic component
stores.
M1226-0050 19
Summary of Contents for BIOFLO III
Page 2: ......
Page 7: ......
Page 9: ...M1226 0050 2...
Page 37: ...M1226 0050 30...
Page 40: ...M1226 0050 33...
Page 48: ...FIGURE 1 VESSEL SCHEMATIC M1226 0050 41...
Page 49: ...FIGURE 2 SAMPLING SYSTEM M1226 0050 42...
Page 50: ...FIGURE 3 FLOWMETER CONVERSION M1226 0050 43...
Page 51: ...FIGURE 4 FRONT PANEL M1226 0050 44...
Page 52: ...FIGURE 5 REAR OF CABINET M1226 0050 45...
Page 53: ...FIGURE 6 SWITCH PANEL M1226 0050 46...
Page 54: ...FIGURE 7 EXTERNAL NUTRIENT PUMP TERMINAL M1226 0050 47...
Page 55: ...FIGURE 8 SUGGESTED IMPELLER LOCATION M1226 0050 48...
Page 56: ...FIGURE 9 HEADPLATE M1226 0050 49...
Page 57: ...FIGURE 10 SPARGER TUBE M1226 0050 50...
Page 58: ...FIGURE 11 HARVEST TUBE M1226 0050 51...
Page 59: ...FIGURE 12 THERMOWELL M1226 0050 52...
Page 60: ...FIGURE 13 FOAM PROBE M1226 0050 53...
Page 61: ...FIGURE 14 BAFFLE INSTALLATION M1226 0050 54...
Page 62: ...FIGURE 15 SIDE PORTS M1226 0050 55...
Page 63: ...FIGURE 16 pH PROBE INSTALLATION M1226 0050 56...
Page 64: ...FIGURE 17 D O PROBE PHOENIX INSTALLATION M1226 0050 57...
Page 65: ...FIGURE 18 D O PROBE INGOLD INSTALLATION M1226 0050 58...
Page 66: ...FIGURE 19 CONVERSION OF D O PORT TO INOCULATION PORT M1226 0050 59...
Page 67: ...FIGURE 20 EXHAUST CONDENSER INSTALLATION M1226 0050 60...
Page 68: ...FIGURE 21 RESTRICTOR IN CONDENSER WATER IN LINE M1226 0050 61...
Page 69: ...FIGURE 22 DISASSEMBLY OF CONDENSER M1226 0050 62...
Page 70: ...FIGURE 23 FACTOR AFFECTING pH CONTROL M1226 0050 63...
Page 86: ...M1226 0050 79...
Page 87: ...FIGURE 25 BEARING HOUSING ASSEMBLY M1226 0050 80...
Page 88: ...FIGURE 26 BEARING HOUSING IN STERILIZATION M1226 0050 81...
Page 89: ...M1226 0050 82...
Page 90: ...M1226 0050 83...
Page 91: ...M1226 0050 84...
Page 92: ...M1226 0050 85...