Chapter 2: Configuring System Information
|
49
FS728TP Smart Switch Software Administration Manual
2.
Configure or view the settings:
•
Admin Mode
. Enable or disable the ability of the port to deliver power.
•
Priority Level
. Determine which ports can deliver power if the total power delivered
by the switch crosses a certain threshold. The switch may not be able to supply power
to all connected devices. Priority is used to determine which ports can supply power.
When ports have the same priority, the lower numbered port is given a higher priority.
•
Detection Mode. Select the detection mode to be used on the port. The detection
mode can be one of the following modes:
•
Legacy Only
: Select this option if only Legacy (capacitive signature) PDs need to
be detected.
•
802.3af 2point Only
: Select this option if only IEEE 802.3af (resistive signature)
PDs need to be detected using two collected samples. This is the default mode.
•
802.3af 4point Only
: Select this option if only IEEE 802.3af (resistive signature)
PDs need to be detected using four collected samples.
•
802.3af 2point and Legacy
:
Select this option to use both Legacy and IEEE
802.3af 2point methods to detect PDs.
•
802.3af 4point and Legacy
: Select this option to use both Legacy and IEEE
802.3af 2point methods to detect PDs.
•
Class
. View the class of the PD connected to the port. The class defines the range of
power a PD is drawing from the system. The class is defined as:
•
0
: 0.44–12.95W
•
1
: 0.44–3.83W
•
2
: 3.84–6.48W
•
3
: 6.49–12.95W
•
4
: Reserved
•
Timer Schedul
e. Select the timer schedule to use for the port. By default, no timer
schedules are configured. To create a timer schedule, use the Timer Global
Configuration page.
•
Output Voltage
. Shows the current voltage being delivered to device in Volts.
•
Output Current
. Shows the current being delivered to device in mA.
•
Output Power
. Shows the current power being delivered to device in Watts.
•
Power Limit Type
. Select the type of power limit to use on the port, which is one of
the following:
•
Class
: Select this option to base the power limit on the detected class value.
When this value is selected, the user-configured value configured in the Power
Limit field is ignored.
•
User
: Select this option to base the power limit on the value configured in the
Power Limit field.
•
Power Limit
. Set the maximum amount of power that can be delivered by a port.
Summary of Contents for FS728TP - ProSafe 24 Port 10/100 Smart Switch
Page 8: ...FS728TP Smart Switch Software Administration Manual 8 Table of Contents ...
Page 188: ...188 Chapter 5 Managing Device Security FS728TP Smart Switch Software Administration Manual ...
Page 231: ...Chapter 8 Help 231 FS728TP Smart Switch Software Administration Manual ...
Page 261: ...Index 261 FS728TP Smart Switch Software Administration Manual ...