E5600SG controller error codes
These codes represent error conditions that might be shown on the E5600SG controller as the
appliance boots up. Additional two-digit hexadecimal codes are displayed if specific low-level
hardware errors occur. If any of these codes persists for more than a second or two, or if you are
unable to resolve the error by following one of the prescribed troubleshooting procedures, contact
technical support.
Code
Indication
22
No master boot record found on any boot device.
23
No SATA drive installed.
2A, 2B
Stuck bus, unable to read DIMM SPD data.
40
Invalid DIMMs.
41
Invalid DIMMs.
42
Memory test failed.
51
SPD reading failure.
92 to 96
PCI bus initialization.
A0 to A3
SATA drive initialization.
AB
Alternate boot code.
AE
Booting OS.
EA
DDR3 training failed.
E8
No memory installed.
EU
The installation script was not found.
EP
"ManageSGA" code indicates that pregrid communication with the E2700 controller
failed.