The cam handle raises slightly when the fan module is completely seated.
9. Swing the cam handle up to its closed position, making sure that the cam handle release latch clicks into
the locked position.
The Attention LED should not be lit after the fan is seated and has spun up to operational speed.
10. Align the bezel with the ball studs, and then gently push the bezel onto the ball studs.
11. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
page for further information.
Replace an NVDIMM - FAS8300 and FAS8700
You must replace the NVDIMM in the controller module when your system registers that
the flash lifetime is almost at an end or that the identified NVDIMM is not healthy in
general; failure to do so causes a system panic.
All other components in the system must be functioning properly; if not, you must contact technical support.
You must replace the failed component with a replacement FRU component you received from your provider.
Step 1: Shut down the impaired controller
You can shut down or take over the impaired controller using different procedures,
depending on the storage system hardware configuration.
495