install one or more X91148A NIC modules into your fully-populated system.
Steps
1. If you are adding an X91148A module into a slot that contains a NIC module with the same number of ports
as the X91148A module, the LIFs will automatically migrate when its controller module is shut down. If the
NIC module being replaced has more ports than the X91148A module, you must permanently reassign the
affected LIFs to a different home port. See
for information about using System Manager to
permanently move the LIFs
2. Shut down controller A:
a. Disable automatic giveback:
storage failover modify -node local -auto-giveback
false
b. Take over the target node:
storage failover takeover -ofnode
target_node_name
The console connection shows that the node drops to the LOADER prompt when the takeover is
complete.
3. If you are not already grounded, properly ground yourself.
4. Unplug any cabling on the target I/O module.
5. Remove the target I/O module from the chassis:
a. Depress the lettered and numbered cam button.
The cam button moves away from the chassis.
b. Rotate the cam latch down until it is in a horizontal position.
The I/O module disengages from the chassis and moves about 1/2 inch out of the I/O slot.
c. Remove the I/O module from the chassis by pulling on the pull tabs on the sides of the module face.
Make sure that you keep track of which slot the I/O module was in.
679