POC-300 Series
80
3.8.5
Operation Modes of Ignition Power Control
You can use the rotary switch to configure the operation mode. The system offers 16
(0~15) operation modes with different power-on/power-off delay configurations.
The ignition control module is also BIOS-configurable. When rotary switch is set to
mode 15 (0xF), the ignition power control is set to executed according to parameters
configured in BIOS setup menu, which allows richer combination of power-on/
power-off delay and more detailed control parameters.
Mode 0
Mode 0 is the ATX mode without power-on and power-off delay. User can only
use the power button on the front panel to turn on or turn off the system.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
0
N/A
N/A
N/A
Mode 1
Mode 1 is AT mode without power-on and power-off delay. The system
automatically turns on when DC power is applied. A retry mechanism is
designed to repeat the power-on cycle if the system fails to boot up.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
1
N/A
N/A
N/A
Mode 2
Mode 2 is designed to have a very minor power on/ off delay of 160ms for
applications that requires the system to start up almost at the same as the rest
of the equipment it is working in collaboration with.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
2
160ms
160ms
10 minutes
Summary of Contents for POC-300
Page 1: ...Neousys Technology Inc POC 300 Series User Manual Revision 1 0 ...
Page 4: ...Table of Contents 4 StopDICOS 108 DI COS Example 108 ...
Page 21: ...POC 300 Series 21 1 5 2 Front Panel View NOTE All measurements are in millimeters mm ...
Page 22: ...POC 300 Series 22 1 5 3 Bottom View NOTE All measurements are in millimeters mm ...
Page 58: ...POC 300 Series 58 5 Reinstall the system enclosure ...