FlexPAK
4.2.17 TVFDAdv
Menu for activating the advanced TVFD where an upper and a lower position sensor are used to detect TVFD
valve position.
ESC
OK
TVFDAdv
1/1
Switch = Off
Switch=Off is the default setting; advanced TVFD is deactivated. Simple
TVFD, AEB or pre-separator is activated.
To activate advanced TVFD, set Switch=On.
4.2.18 PSCFlush
Menu for activating flushing of the duct system. When ‘Switch=Off’, flushing is timer controlled. When
‘Switch=On’, flushing is controlled by the pilot signal; flushing takes place when the pilot signal disappears. See
and
ESC
OK
PSCFlush 1/1
Switch = Off
Switch=Off is the default setting. PSCFlush is deactivated.
To activate PSCFlush set Switch=On.
4.2.19 Auto Empt
Menu for activating the Automatic Emptying of collector Bin interval Timer (AEBTme), see
.
ESC
OK
BinAuto 1/1
Switch = Off
Switch=Off is the default setting; the BinAuto timer is off.
To activate the AEBTme timer, set Switch=On.
4.2.20 LiAuto
Menu for activating Bin Level Indicator Automatic Emptying of Bin (BLI-Empt), see
.
ESC
OK
LIAuto
1/1
Switch = Off
Switch=Off is the default setting; LiAuto is deactivated
To activate LiAuto, set Switch=On.
4.2.21 LSOTmr
Menu for setting the amount of time the TVFD Solenoid Lower Valve (SLV) is open for bin emptying. LSOTmr is
only used if TVFDAdv is activated (Switch=On). This message is only used when TVFD advanced is activated
LSOTmr cannot be set to a value equal to or greater than TVFDO-Al, LSOTmr < TVFDO-Al.
ESC
OK
LSOTmt
1/1
T
= 10:00s
Ta = 00:00s
T=10:00s: Amount of time the SLV to be open. The default setting is 10
seconds.
Ta=00:00: The elapsed time since SLV has been opened.
33