Table 3-3-1
Camera Link Connector (26-pin MDR Connector) pin assignments
CL1(Base Configuration) CL2(Medium Configuration)
No
NAME
No
NAME
I/O
1
Inner Shield
14
Inner Shield
2
X0-
15
X0+
Out
3
X1-
16
X1+
Out
4
X2-
17
X2+
Out
5
Xclk-
18
Xclk+
Out
6
X3-
19
X3+
Out
7
SerTC+
20
SerTC-
In
8
SerTFG-
21
Out
9
CC1-
22
CC1+
In
10
CC2+
23
CC2-
In
11
CC3-
24
CC3+
In
12
CC4+
25
CC4-
In
13
Inner Shield
26
Inner Shield
Explanation of Signals
Inner Shield :
Shield cable (GND)
X0+,X0-
…X3+,X3- : Data output (Channel Link)
Xclk+,Xclk- :
Clock output for above data output synchronization (Channel Link)
Y0+,Y0-
…Y3+,Y3- : Data output (Channel Link)
Yclk+,Yclk- :
Clock output for above data output synchronization (Channel Link)
SerTC+, SerTC- : Serial data input (LVDS)
, SerTFG- : Serial data output (LVDS)
CC1+,CC1- :
External synchronous signal input (LVDS)
CC2+,CC2- :
Not in use (LVDS)
CC3+,CC3- :
Not in use (LVDS)
CC4+,CC4- :
Not in use (LVDS)
Camera Link compatible cable
14B26 - SZLB - xxx - 0LC by 3M (or equivalent)
To avoid uncoupling of cable connectors during power on, make sure to clamp
them with locking screws.
Do not unplug the cable while power is being supplied to the camera.
No
NAME
No
NAME
I/O
1
Inner Shield
14
Inner Shield
2
Y0-
15
Y0+
Out
3
Y1-
16
Y1+
Out
4
Y2-
17
Y2+
Out
5
Yclk-
18
Yclk+
Out
6
Y3-
19
Y3+
Out
7
100
Ω
terminated
20
100
Ω
terminated
8
Open
21
Open
9
100
Ω
terminated
22
100
Ω
terminated
10
100
Ω
terminated
23
100
Ω
terminated
11
100
Ω
terminated
24
100
Ω
terminated
12
100
Ω
terminated
25
100
Ω
terminated
13
Inner Shield
26
Inner Shield