NED
XCM8060SA_8040SA_6040SA
UME-0034-03
28
Exposure-Readout Time
pad
0 to
50
0 - 54613
μs
(
XCM8060SA
)
0 - 81920
μs
(
XCM8040SA
)
0 - 61440
μs
(
XCM6040SA
)
Operation Status Readout
sta
Returns the current camera settings.
Scanning Direction
rev
0 /1
0 : Forward / 1 : Reverse
Programmable Exposure Time
=
VAL2
÷
{[X]
÷
(16
x
2
^
VAL1)}
Exposure-Readout Time
=
VAL1
÷
{[X]
÷
(16
x
2
^
VAL1*)} The VAL1* is VAL1 of
Programmable Exposure Time item.
XCM8060SA : [X]=30000000,
XCM8040SA : [X]=20000000,
XCM6040SA : [X]=26666667
4.1.5 Memory Setup Values (Factory Settings)
The memory setup values (factory settings) are shown below.
Table 4-1-5-1 Memory Setup Values (Factory Settings)
Control Item
CMD
VAL1
VAL2
VAL3
Control Description
Analog Gain
gax
0
x1(0dB)
Digital Gain
gdx
0
x1
Digital Offset
odx
0
0DN
(8 bit)
Exposure Mode
inm
0
Free Run
Programmable Exposure
Time
int
0
61
32.5
μs (XCM8060SA)
48.8
μs (XCM8040SA)
36.6
μs (XCM6040SA)
(Dividing=16
、
Counter=61)
Output Signal Setting 1
voa
0
0
8 bit, 8192 pixel
Output Signal Setting 2
voc
0
linear
Setting Multi-Slope level
msl
0
5
10
3 Slope settings
Setting Multi-Slope timing
mst
0
1
10
3 Slope settings
Test Pattern
tpn
0
OFF
Pixel Correction Setting
shc
1
600
Factory White Correction
Correction Level 600DN(10 bit)
(XCM8040SA)
900DN(10
bit)
(XCM8060SA/XCM6040SA)
Exposure-Readout Time
pad
0
0
μs
Scanning Direction
rev
0
Forward : 0