Figure 25 - Install cord grips
INSTALL CORD
GRIPS ALL
LOCATIONS
TILT SWITCH
CORD
Figure 26 - Drill holes / wire ties to secure cords
AUGER
MOTOR(S)
CORD
DRILL HOLES - USE
WIRE TIES TO
SECURE CORDS
NOTE:
Schematic choices are based on input voltage and if the equipment has the optional
Stall Timer (See EQUIPMENT OVERVIEW section for this optional equipment description).
Choose the correct schematic for your application and install electrical cords per the following:
• Install cord grips at ALL locations where electrical cords enter - See Figure 25.
Cords: 1. Rotating Contactor Cord
2. Auger Motor Cord
3. Tilt Switch Cord
4. Optional Stall Tmer Cord
5. Gear Motor Cord
• Drill 3/16” holes along the top channel edge and use the supplied wire ties to secure cords
where necessary - See Figure 26.
• Leave approximately 6 to 7 inches of wire inside the box, strip the insulation from inside wires,
and provide approximately 3/8” bare wire for wire nut or terminal applications.
• Make sure that all cords have sufficient travel, along with approximately 12” of cord drop prior
to securing cord grips.
Figure 27 - Route Cords
GEAR MOTOR
CORD
Figure 28 - Final hookup per schematic
AUGER MOTOR
CORDS
GEAR MOTOR
CORD
STALL TIMER
CORD
TILT SWITCH
CORD
CONTACTOR
CORD
Summary of Contents for STIR-RITE III
Page 30: ...30 SCHEMATIC 460V 3PH WITH NO STALL TIMER...
Page 32: ...32 SCHEMATIC 230V 1PH 3PH WITH STALL TIMER NOTE Set the stall timer to 45 minutes...
Page 33: ...33 SCHEMATIC 460V 3PH WITH STALL TIMER NOTE Set the stall timer to 45 minutes...
Page 48: ...48 STIR RITE III OVERALL ASSEMBLY REPLACEMENT PARTS...
Page 54: ...54 TROLLEY ASSEMBLY...