Step 1.
Obtain a measurment from the top of
peak ring to the BOTTOM MOST POSSIBLE
EXTENSION OF THE SPREADER DESIGN.
NOTE: Various spreader designs may have
pans that can hinge lower, etc. Make sure to
allow for enough clearance for total spreader
adjustment area.
Step 2.
Take the actual spreader clearance
value and add 3 to 4 inches of safety clearance
and then add the 49 inch reference value.
Mark this level upon bin wall and verify that the
mark is a MINIMUM if 10 1/4 inches below the
eave level or the top of the bin wall. Increase the
10 1/4 inch clearance if needed.
DETERMINE SPREADER CLEARANCE
FINAL VERIFICATION:
Double-check with positioning an actual track section with bracket. If ev-
erything is correct, procede with “TRACK INSTALLATION”. Also, refer back to Figure 3A and note
the required “1/8” per foot beam rise toward bin center” that is recommended.