26
8. Position either size junchion box on the back of the
pivot arm frame and align it with the mounting holes.
Note that the #039239 box uses the two center holes
for mounting and that the #002192 box uses the four
outside holes for mounting.Attach the junction box
using self-tapping screws. See Figure 24.
Mount the Junction Box
to Pivot Arm Frame
Figure 24 - Mount the Junction Box
The customer is responsible for providing materials and labor to the equipment, including a
properly sized and fused disconnect box. See the table below for amperage requirements
based on input voltage and the number of down augers in the system. All materials and
work should conform to local, state, and national electrical codes.
NECO strongly suggests contacting your local electrician.
• The bin must be grounded properly.
• Do not operate the equipment with any electrical covers removed. The cover not only
protects from electrical shock, but also keeps grain, dust, and moisture out of the box.
• DO NOT run the equipment in an empty bin for any reason.
CAUTION
PHASE
AC VOLTS
# OF DOWN
AUGERS
MAIN DISCONNECT AMPERAGE REQ’D
1
230
1 - 2
30 AMP
1
230
3 - 4
60 AMP
3
230
1 - 4
30 AMP
3
460
1 - 4
15 AMP
AMPERAGE REQUIREMENTS
NOTE:
The following table shows system amperage requirements based on input voltage
and the number of down augers. See “INSTALL MAIN DISCONNECT SWITCH” for additional
information.
Summary of Contents for STIR-RITE III
Page 30: ...30 SCHEMATIC 460V 3PH WITH NO STALL TIMER...
Page 32: ...32 SCHEMATIC 230V 1PH 3PH WITH STALL TIMER NOTE Set the stall timer to 45 minutes...
Page 33: ...33 SCHEMATIC 460V 3PH WITH STALL TIMER NOTE Set the stall timer to 45 minutes...
Page 48: ...48 STIR RITE III OVERALL ASSEMBLY REPLACEMENT PARTS...
Page 54: ...54 TROLLEY ASSEMBLY...