Chapter 9
Timer / Counter (Real Time Pulse Unit)
Preliminary User’s Manual U14913EE1V0UM00
9.1.5 Operation
(1)
Compare operation
TMDn can be used for a compare operation in which the value that was set in a compare register
(CMDn) is compared with the TMDn count value (n = 0, 1).
If a match is detected by the compare operation, an interrupt (TINTCMDn) is generated. The gener-
ation of the interrupt causes TMDn to be cleared (0) at the next count timing. This function enables
timer D to be used as an interval timer.
CMDn can also be set to 0. In this case, when an overflow occurs and TMDn becomes 0, a match is
detected and TINTCMDn is generated. Although the TMDn value is cleared (0) at the next count
timing, TINTCMDn is not generated according to this match.