Chapter 4 Standard Mode
4-7
NWA-033628-001 Rev.1.0
[Implement] Category
System Data All Clear (CM00/CMEC)
Execute System Data All Clear on the SV8300 in the following steps:
STEP1:
Click the [1] button [Quick Setup] screen.
The [1. All-Clear of System Data] screen is displayed in the work window.
STEP2:
Set the [SENSE] switch to “E” on the CPU blade mounted in the SV8300.
STEP3:
Press the [RESET] button on the CPU blade to reset.
Press the CPU blade [RESET] button and the lamps will change in their states as described
below.
STEP4:
Check that the SV8300 has restarted.
Check that the RUN lump on the CPU blade indicates a normal operating state.
STEP5:
Reconnect the communication link with the SV8300
Clear the communication link: click [System] > [Disconnect] (
), then estab-
lish the link: click [System] > [Connect] (
).
Change
Lamp states
RUN
SYSD
SI
Press the [RESET]
button
Off
Off
Off
↓
Blinking blue fast
Off
Blinking green fast
↓
Blinking blue fast
Blinking red fast
Off
Normal state
Blinking blue
slowly
Off
Off