12
PROJECTION CONFIGURATION CHANGE
3
Loosen the four screws B, then lift the upper chassis(DFC).
• B is a retaining screw.
4
Reverse the convergence connectors (AR, BR, AG, BG, AB and BB) on CONV-DRIVE.
See Table below.
Connector pin
Setting
Ceiling front
Desk top front
Ceiling rear
Desk top rear
AR,AG,AB
1
Lead
Red
Blue
Blue
Red
2
Lead
Blue
Red
Red
Blue
BR, BG, BB
1
Lead
Yellow
Brown
Yellow
Brown
2
Lead
Brown
Yellow
Brown
Yellow
NOTE: The table is for non mirror applications.
Convergence polarity change
1
2
Red
Blue
Yellow
Brown
BR
AG
BG
AB
BB
AR
5
Close the upper chassis (DFC). Tighten the four screws B.
B