Updating Management Firmware using Remote console interface
2-4
member cell of the partition that is AC powered on. The update takes several
minutes to complete. Initially, a dialog box is displayed saying that the update is in
progress. When the update finishes, all cells should have the same firmware level.
Each Service Processor performs a reset action, and the connection to the remote
console interface is lost.
3. Refresh the page and log on to restore the partition remote console interface.
4. Navigate to the firmware update page and click
Display Current Firmware Status
and Revision
to check that the current management firmware level is correct.
A dialog box appears containing the current management firmware revision level for
each cell in the partition, as shown in
Figure 2-4
. All cells in the partition should
have the same firmware level.
Note: If a cell is not listed in the dialog box, it is AC powered off or otherwise not
communicating properly.
Figure 2-4 Management Firmware Revision Status