CHAPTER 4 CIRCUIT CARD INFORMATION
– 276 –
ND-71503(E) Rev.5.0
9pch4001.fm
NOTE 5:
When using Series 3300 R8 software or later in the system, mount the IP-PAD (PN-8IPLA) card
as shown below.
The required slot for the IP-PAD (PN-8IPLA) card depends on the using number of channel in
the IP-PAD card.
Do not mount any other L/T cards in LT08-LT10 slots (AP cards are mountable in AP08-AP10
slots).
• When using IP-PAD (PN-8IPLA) card with 8-channel
Required slot: LT00/LT04
• When using IP-PAD (PN-8IPLA) card with 16-channel
Required slots: LT00/LT04 and one adjoining slot (LT01/LT05)
Only AP cards are mountable in LT01/LT05.
• When using IP-PAD (PN-8IPLA) card with 24-channel
Required slots: LT00/LT04 and two adjoining slots (LT01/LT02, LT05/LT06)
Only AP cards are mountable in LT01/LT02, LT05/LT06.
• When using IP-PAD (PN-8IPLA) card with 32-channel
Required slots: LT00/LT04 and three adjoining slots (LT01/LT02/LT03, LT05/LT06/LT07)
Only AP cards are mountable in LT01/LT02/LT03, LT05/LT06/LT07.
NOTE 6:
When using Series 3200 R6.2 software or before in the system, mount the IP-PAD (PN-8IPLA)
card in LT01/LT05 slot.
JANUARY/16/2004
MOUNTING LOCATION OF CIRCUIT CARDS