CHAPTER 3 SYSTEM DATA PROGRAMMING
– 118 –
ND-71503(E) Rev.5.0
9pch3001.fm
Time Zone/Daylight Saving Time Data Assignment
[Series 3300 software required]
To enable remote connection of stations regardless of nation and area with multiple time zone, do the fol-
lowing programming.
DESCRIPTION
DATA
Assign the Location number to each remote
site.
•
(1)
(2)
Y=31-60 (Remote Site No. 01-30)
40
00-63: Location No.
Assign the Time Zone to each location.
•
(1)
(2)
Y=10
00-63: Location No.
Time Zone (See the table below)
NONE : No Time Zone
NOTE 1:
System clock should be assigned by CM02.
NOTE 2:
After changing the data, office data copy to Remote Site by CMEC Y=8 is required.
Assign the Daylight Saving Time to each loca-
tion.
NOTE:
After changing the data, office data
copy to Remote Site by CMEC Y=8
is required.
•
(1)
(2)
Y=30
00-63: Location No.
0: Daylight Saving Time (+1 hour)
NONE : No Daylight Saving Time
START
CM0B
CM67
+15 minute increments
2nd Data
Time Zone
A2345
System Clock +23:45
A2330
System Clock +23:30
A2315
System Clock +23:15
A2300
System Clock +23:00
A0100
System Clock +01:00
A0045
System Clock +00:45
A0030
System Clock +00:30
A0015
System Clock +00:15
NONE
No Time Zone (No time
difference)
-15 minute increments
2nd Data
Time Zone
B0015
System Clock -00:15
B0030
System Clock -00:30
B0045
System Clock -00:45
B0100
System Clock -01:00
B2300
System Clock -23:00
B2315
System Clock -23:15
B2330
System Clock -23:30
B2345
System Clock -23:45
CCC
Time Zone data clear
END
SEPTEMBER/15/2004
REMOTE PIM OVER IP DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn