CHAPTER 3 SYSTEM DATA PROGRAMMING
– 237 –
ND-71503(E) Rev.5.0
9pch3002.fm
14. In following conditions, fault messages output by Trap might disappear. This is because SNMP is op-
erated on UDP and communication is made without establishing the connection. Besides, since UDP
does not resend messages, abandoned data cannot be retrieved again.
[Series 3200 R6.2 software required]
– SNMP manager is not started
– Network traffic is congested
– Fault occurs on the line between PBX and SNMP manager
Fault Kind Code
Fault Description
34
The number of faulty trunks was less than the predetermined number
35
The number of lockout station restored to less than the predetermined number
36
DLC Card returned to normal condition
38
SMDS output buffer memory returned to normal condition
3A
Recording -unit fault occurrence returned to normal condition
3B
CS/ZT returned to normal condition
40
Traffic of IP network exceeded limit bandwidth
41
Traffic of IP network exceeded warning bandwidth
42
Communication error occurrence between Main Site and Remote Site
50
Traffic of IP network returned to normal condition from limit bandwidth excess
51
Traffic of IP network returned to normal condition from warning bandwidth excess
52
Communication error restoration between Main Site and Remote Site