Maintenance Manual
Page 10
ND-70926
(E),
Issue
3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
(2)
To clear the MJ/MN alarm by external key:
(3)
To set Alarm Kind of Fault Information via MATWorX:
Please consult the Online Help included with MATWorX.
NOTE 1: CM08>450, 451 cannot be set by MATWorX.
NOTE 2: Some Standard settings of the fault kind cannot be changed by MATWorX.
DESCRIPTION
DATA
Assign the card number for External
Key Interface (PN-DK00) to the
desired LEN.
NOTE 1: The card number of the
External Key Interface (PN-
DK00) must be assigned to
the first LEN (LEVEL 0) and
third LEN (LEVEL 2) of each
card slot.
NOTE 2: Circuit No. 3 of E963 is used
for built-in External Key
Interface of MP card by
setting CM61.
(1)
(2)
000-763: LEN
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For PIM0/1: E900-E915
For PIM2/3: E916-E931
For PIM4/5: E932-E947
For PIM6/7: E948-E963
Assign the function of MJ/MN alarm
clear key to the external key.
•
(1)
(2)
YY=30
XX Z
XX : 00-63 : Card No. of PN-DK00
Z
: 0-3
: Circuit No.
633 : MP built-in External Key Interface
00 : MJ/MN alarm clear key
CM61
CM10
START
END